Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
AJNR Am J Neuroradiol ; 43(2): 188-194, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34992128

RESUMO

BACKGROUND AND PURPOSE: MR imaging is the technique of choice for follow-up of patients with brain metastases, yet the radiologic assessment is often tedious and error-prone, especially in examinations with multiple metastases or subtle changes. This study aimed to determine whether using automated color-coding improves the radiologic assessment of brain metastases compared with conventional reading. MATERIALS AND METHODS: One hundred twenty-one pairs of follow-up examinations of patients with brain metastases were assessed. Two radiologists determined the presence of progression, regression, mixed changes, or stable disease between the follow-up examinations and indicated subjective diagnostic certainty regarding their decisions in a conventional reading and a second reading using automated color-coding after an interval of 8 weeks. RESULTS: The rate of correctly classified diagnoses was higher (91.3%, 221/242, versus 74.0%, 179/242, P < .01) when using automated color-coding, and the median Likert score for diagnostic certainty improved from 2 (interquartile range, 2-3) to 4 (interquartile range, 3-5) (P < .05) compared with the conventional reading. Interrater agreement was excellent (κ = 0.80; 95% CI, 0.71-0.89) with automated color-coding compared with a moderate agreement (κ = 0.46; 95% CI, 0.34-0.58) with the conventional reading approach. When considering the time required for image preprocessing, the overall average time for reading an examination was longer in the automated color-coding approach (91.5 [SD, 23.1] seconds versus 79.4 [SD, 34.7 ] seconds, P < .001). CONCLUSIONS: Compared with the conventional reading, automated color-coding of lesion changes in follow-up examinations of patients with brain metastases significantly increased the rate of correct diagnoses and resulted in higher diagnostic certainty.


Assuntos
Neoplasias Encefálicas , Imageamento por Ressonância Magnética , Neoplasias Encefálicas/diagnóstico por imagem , Meios de Contraste , Seguimentos , Humanos , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
2.
J Clin Neurosci ; 89: 33-38, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34119289

RESUMO

BACKGROUND: Complete reperfusion (mTICI 3) in anterior circulation ischemic stroke patients after a single mechanical thrombectomy (MT) pass has been identified as a predictor of favorable outcome (modified Rankin Score 0-2) and defined as true first-pass effect recently. This effect has not yet been demonstrated in posterior circulation ischemic stroke. We hypothesized a true first-pass effect for the subgroup of acute basilar artery occlusions (BAO). METHODS: Consecutive patients with acute thromboembolic occlusions in the posterior circulation, treated between 2010 and 2017, were screened and all BAO patients with complete angiographic reperfusion and known symptom onset included for unmatched and matched analysis after adjustment for multiple confounding factors (demographics, time intervals, stroke severity, posterior circulation Alberta Stroke Program early computed tomography Score and comorbidity. The primary objective was outcome at 90 days between matched cohorts of single pass vs. multi pass complete reperfusion patients. RESULTS: 90 MTs in BAO were analyzed, yielding 56 patients with known symptom onset, in whom we achieved complete reperfusion (mTICI 3), depending on whether complete reperfusion was achieved after a single pass (n = 28) or multiple passes (n = 28). Multivariable analysis of 56 non-matched patients revealed a significant association between first-pass complete reperfusion and favorable outcome (p < 0.01). In matched cohorts (n = 7 vs. n = 7), favorable outcome was only seen if complete reperfusion was achieved after a single pass (86% vs. 0%). CONCLUSION: Single pass complete reperfusion in acute basilar artery occlusion is an independent predictor of favorable outcome. Achieving complete reperfusion after multiple passes might impair favorable patient recovery.


Assuntos
Artéria Basilar/cirurgia , Revascularização Cerebral/métodos , Transtornos Cerebrovasculares/cirurgia , Acidente Vascular Cerebral/cirurgia , Trombectomia/tendências , Idoso , Idoso de 80 Anos ou mais , Artéria Basilar/diagnóstico por imagem , Transtornos Cerebrovasculares/complicações , Transtornos Cerebrovasculares/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reperfusão/métodos , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Trombectomia/métodos , Resultado do Tratamento
3.
AJNR Am J Neuroradiol ; 42(4): 655-662, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33541907

RESUMO

BACKGROUND AND PURPOSE: Malignant melanoma is an aggressive skin cancer in which brain metastases are common. Our aim was to establish and evaluate a deep learning model for fully automated detection and segmentation of brain metastases in patients with malignant melanoma using clinical routine MR imaging. MATERIALS AND METHODS: Sixty-nine patients with melanoma with a total of 135 brain metastases at initial diagnosis and available multiparametric MR imaging datasets (T1-/T2-weighted, T1-weighted gadolinium contrast-enhanced, FLAIR) were included. A previously established deep learning model architecture (3D convolutional neural network; DeepMedic) simultaneously operating on the aforementioned MR images was trained on a cohort of 55 patients with 103 metastases using 5-fold cross-validation. The efficacy of the deep learning model was evaluated using an independent test set consisting of 14 patients with 32 metastases. Manual segmentations of metastases in a voxelwise manner (T1-weighted gadolinium contrast-enhanced imaging) performed by 2 radiologists in consensus served as the ground truth. RESULTS: After training, the deep learning model detected 28 of 32 brain metastases (mean volume, 1.0 [SD, 2.4] cm3) in the test cohort correctly (sensitivity of 88%), while false-positive findings of 0.71 per scan were observed. Compared with the ground truth, automated segmentations achieved a median Dice similarity coefficient of 0.75. CONCLUSIONS: Deep learning-based automated detection and segmentation of brain metastases in malignant melanoma yields high detection and segmentation accuracy with false-positive findings of <1 per scan.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Melanoma , Neoplasias Cutâneas , Automação , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/secundário , Humanos , Imageamento por Ressonância Magnética , Melanoma/diagnóstico por imagem , Melanoma/secundário , Neoplasias Cutâneas/diagnóstico por imagem
4.
AJNR Am J Neuroradiol ; 42(3): 516-523, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33384288

RESUMO

BACKGROUND AND PURPOSE: CTA provides a noninvasive alternative technique to DSA in the follow-up after endovascular aneurysm treatment to evaluate aneurysm occlusion and exclude intraluminal narrowing after stent or flow-diverter implantation; however, assessability may be impeded by stent material artifacts. The objective of this in vitro study was to compare the visual assessability of different conventional stents and flow diverters as well as different reconstructions of dual-layer CT images. MATERIALS AND METHODS: Four conventional intracranial stents and 4 flow diverters were implanted in identical aneurysm phantoms. Conventional and monoenergetic images (40, 50, 60, 90, 120, 180 keV) were acquired to evaluate attenuation alteration, visible lumen diameter, and SNR. Image quality was rated subjectively by 2 independent radiologists using a 4-point Likert scale. RESULTS: Low kiloelectron volt (40-60 keV) monoenergetic reconstructions showed an improved SNR and an improved lumen density ratio compared with high kiloelectron volt reconstructions (90-180 keV) and conventional reconstructions, however without reaching significance compared with the latter. Assessment of the adjacent aneurysm and subjective evaluation was not affected by the imaging technique and stent type. Artifact susceptibility varied with the device used and increased among flow diverters. CONCLUSIONS: Low kiloelectron volt reconstructions improved the assessment of the stent lumen in comparison with high kiloelectron volt reconstructions. No significant improvement in image quality could be shown compared with conventional images. For some devices, iodine-specific reconstructions led to severe artifacts and are therefore not recommended. There was no relevant improvement in the assessability of the adjacent aneurysm.


Assuntos
Aneurisma/diagnóstico por imagem , Aneurisma/terapia , Angiografia por Tomografia Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Artefatos , Procedimentos Endovasculares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Stents
5.
J Clin Neurosci ; 75: 117-121, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32173154

RESUMO

Stent protected Angioplasty of extracranial carotid artery stenosis using the dual-layered CGUARD stent is a novel treatment option. In this study we evaluate the feasibility and the safety of the CGUARD in symptomatic and asymptomatic patients in comparison to Casper-RX and Wallstent. This is a multi-center study of consecutive patients treated with the CGUARD, Casper-RX and Wallstent at two German high volume neurovascular centers between April 2017 and May 2018. Patient characteristics, neuroimaging data and angiographic outcome were retrospectively analyzed. The primary end points of the study were acute occlusion of the carotid stent and symptomatic intracerebral hemorrhage (sICH). Carotid artery stenting was performed in 76 patients; of those 26 (34%) were treated with the CGUARD, 25 (33%) with Casper-RX, and 25 (33%) with Wallstent. In 58/76 (76%) cases carotid artery stenosis was symptomatic with a median baseline National Institutes of Health Stroke Scale of 4. Angioplasty and stenting as part of a mechanical thrombectomy for acute ischemic stroke was performed in 25/76 (33%) patients. Baseline patient characteristics were similar between the treatment groups, except for a higher portion of scheduled cases in the Casper-RX group. There were no significant differences in the rate of acute in stent occlusions (CGUARD, 2/26 (8%); Casper-RX, 1/25(4%); Wallstent, 1/25 (4%)) and postinterventional sICH (1/26 (4%), 0/25(0%), 0/25 (0%)). Clinical outcome at discharge did not differ between groups. Treatment of carotid artery stenosis using CGUARD is feasible with a good safety profile comparable to that of Casper-RX and Wallstent.


Assuntos
Estenose das Carótidas/terapia , Stents/normas , Idoso , Angioplastia/métodos , Isquemia Encefálica/terapia , Estenose das Carótidas/cirurgia , Procedimentos Endovasculares/métodos , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/terapia , Resultado do Tratamento
6.
AJNR Am J Neuroradiol ; 40(10): 1617-1623, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31537517

RESUMO

BACKGROUND AND PURPOSE: Our aim was to evaluate whether improved gray-white matter differentiation in cranial CT by means of 65- keV virtual monoenergetic images enables a radiation dose reduction compared to conventional images. MATERIALS AND METHODS: One hundred forty consecutive patients undergoing 171 spectral detector CTs of the head between February and November 2017 (56 ± 19 years of age; male/female ratio, 56%/44%) were retrospectively included. The tube current-time product was reduced during the study period, resulting in 61, 55, and 55 patients being examined with 320, 290, and 260 mAs, respectively. All other scanning parameters were kept identical. The volume CT dose index was recorded. ROIs were placed in gray and white matter on conventional images and copied to identical positions in 65- keV virtual monoenergetic images. The contrast-to-noise ratio was calculated. Two radiologists blinded to the reconstruction technique evaluated image quality on a 5-point Likert-scale. Statistical assessment was performed using ANOVA and Wilcoxon test adjusted for multiple comparisons. RESULTS: The mean volume CT dose index was 55, 49.8, and 44.7 mGy using 320, 290, and 260 mAs, respectively. Irrespective of the volume CT dose index, noise was significantly lower in 65- keV virtual monoenergetic images compared with conventional images (65- keV virtual monoenergetic images/conventional images: extraocular muscle with 49.8 mGy, 3.7 ± 1.3/5.6 ± 1.6 HU, P < .001). Noise slightly increased with a reduced radiation dose (eg, extraocular muscle in conventional images: 5.3 ± 1.4/5.6 ± 1.6/6.1 ± 2.1 HU). Overall, the contrast-to-noise ratio in 65- keV virtual monoenergetic images was superior to that in conventional images irrespective of the volume CT dose index (P < .001). Particularly, 65-keV virtual monoenergetic images with 44.7 mGy showed significantly lower noise and a higher contrast-to-noise ratio than conventional images with 55 mGy (P < .001). Subjective analysis confirmed better image quality in 65- keV virtual monoenergetic images, even using 44.7 mGy. CONCLUSIONS: The 65-keV virtual monoenergetic images from spectral detector CT allow radiation dose reduction in cranial CT. While this proof of concept included a radiation dose reduction of 19%, our data suggest that even greater reduction appears achievable.


Assuntos
Crânio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Algoritmos , Mapeamento Encefálico , Tomografia Computadorizada de Feixe Cônico , Feminino , Substância Cinzenta/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído , Substância Branca/diagnóstico por imagem
7.
Parkinsonism Relat Disord ; 67: 117-121, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31495733

RESUMO

OBJECTIVE: Lead orientation is a new degree of freedom with directional deep brain stimulation (DBS) leads. We investigated how prevalent deviations from the intended implantation direction are in a large patient cohort. METHODS: The Directional Orientation Detection (DiODe) algorithm to determine lead orientation from postoperative CT scans was implemented into the open-source Lead-DBS toolbox. Lead orientation was analyzed in 100 consecutive patients (198 leads). Different anatomical targets and intraoperative setups were compared. RESULTS: Deviations of up to 90° from the intended implantation direction were observed. Deviations of more than 30° were seen in 42% of the leads and deviations of more than 60° in about 11% of the leads. Deviations were independent from the neuroanatomical target and the stereotactic frame but increased depending on which microdrive was used. DISCUSSION: Our results indicate that large deviations from the intended implantation direction are a common phenomenon in directional leads. Postoperative determination of lead orientation is thus mandatory for investigating directional DBS.


Assuntos
Estimulação Encefálica Profunda , Neuroestimuladores Implantáveis , Transtornos dos Movimentos/terapia , Procedimentos Neurocirúrgicos , Implantação de Prótese/estatística & dados numéricos , Humanos , Período Pós-Operatório , Estudos Retrospectivos , Técnicas Estereotáxicas , Tomografia Computadorizada por Raios X
8.
AJNR Am J Neuroradiol ; 40(10): 1766-1772, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31488499

RESUMO

BACKGROUND AND PURPOSE: The Woven EndoBridge 17 has recently been introduced to the market for facilitated endovascular treatment of small bifurcation aneurysms (≤7 mm) with low-profile microcatheters. We compared the Woven EndoBridge 17 with its predecessor versions in terms of procedural safety and feasibility. MATERIALS AND METHODS: This was a multicenter review of aneurysms ranging from 3 to 7 mm treated with the Woven EndoBridge between 2011 and 2019. Aneurysm characteristics, procedural parameters, and complications were retrospectively compared between treatment with the Woven EndoBridge 17 and a control group that was treated with its predecessor versions, using inverse probability of treatment weighting. RESULTS: Thirty-eight aneurysms treated with a Woven EndoBridge 17 (mean size, 4.9 ± 1.5 mm) and 70 treated with a predecessor version of the Woven EndoBridge 17 (mean size, 5.6 ± 1.4 mm) were included. The predecessor version of the Woven EndoBridge 17 had a higher failure rate (10.3%) than the Woven EndoBridge 17 (0%, P = .05). Additional stent placement was performed more often with the predecessor version of the Woven EndoBridge 17 (10.0%) than with the Woven EndoBridge 17 (2.6%, adjusted P = .005). The predecessor version of the Woven EndoBridge 17 was associated with a higher thromboembolic event rate (14.3%) than the Woven EndoBridge 17 (5.3%, adjusted P = .002). Neurologic complications (Woven EndoBridge 17: 2.6%; predecessor version of the Woven EndoBridge 17: 2.9%, adjusted P = 1.0) and immediate complete aneurysm occlusion rates (Woven EndoBridge 17: 57.9%; predecessor version of the Woven EndoBridge 17: 54.3%, adjusted P = .21) did not differ significantly between groups. CONCLUSIONS: In the current study, the Woven EndoBridge 17 was associated with a potentially lower thromboembolic event rate than the predecessor version of the Woven EndoBridge 17, without compromising the immediate aneurysm occlusion rate. Long-term clinical and angiographic outcome analysis will be necessary to draw a definite conclusion.


Assuntos
Prótese Vascular , Embolização Terapêutica/instrumentação , Procedimentos Endovasculares/instrumentação , Aneurisma Intracraniano/terapia , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular/efeitos adversos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento
9.
Eur Radiol ; 29(11): 5941-5949, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31041562

RESUMO

OBJECTIVE: To evaluate feasibility and diagnostic performance of multi-level calcium suppression in spectral detector computed tomography (SDCT) for assessment of bone metastasis. MATERIALS AND METHODS: Retrospective IRB-approved study on 21 patients who underwent SDCT (120 kV, reference mAs 116) and MRI. Thoracic and lumbar vertebrae (n = 357) were included and categorized as normal (n = 133) or metastatic (n = 203) based on MRI (STIR, T1w, ±contrast). The multi-level virtual non-calcium (VNCa) algorithm computes dynamic soft tissue/calcium pairs allowing for computation of different suppression index levels to address inter-individual variance of prevalent calcium composition weights. We computed images with low, medium, and high calcium suppression indices and compared them with conventional images (VNCa_low/med/high and conventional images (CI)). For quantitative image analysis, regions of interest were placed in normal and metastatic bone. Two readers reviewed the datasets independently in multiple sessions. They determined the presence of vertebral metastases on a per vertebra basis using a binary scale. Statistic assessment was performed using ANOVA with Tukey HSD, Student's T test, and ROC analysis. RESULTS: Attenuation of both normal and metastatic bone was lower in VNCa images than that in conventional images (e.g., CI/VNCa_low, - 46.3 to 238.8 HU/343.3-60.2 HU; p ≤ 0.05). VNCa_low+med improved separation of normal and metastatic bone in ROC analysis (AUC, CI/VNCa_low/VNCa_med = 0.74/0.95/0.98; p ≤ 0.05). In subjective analysis, both sensitivity and specificity were clearly improved in VNCa_low as compared with CI (0.85/0.84 versus 0.78/0.82). Readers showed a good inter-rater reliability (kappa = 0.65). CONCLUSIONS: Multi-level VNCa reconstructed from SDCT improve quantitative separation of normal and metastatic bone and subjective determination of bone metastases when using low to intermediate calcium suppression indices. KEY POINTS: • Spectral detector CT allows for multi-level calcium suppression in CT images and low and medium calcium suppression indices improved separation of normal and metastatic bone. • Thus, multi-level calcium suppression allows to optimize image contrast in regard to dedicated pathologies. • Low-level virtual non-calcium images (index 25-50) improved diagnostic performance regarding detection of metastasis.


Assuntos
Doenças da Medula Óssea/diagnóstico por imagem , Cálcio , Neoplasias da Coluna Vertebral/secundário , Tomografia Computadorizada por Raios X/métodos , Adulto , Algoritmos , Medula Óssea/diagnóstico por imagem , Métodos Epidemiológicos , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Vértebras Torácicas/diagnóstico por imagem
10.
Eur J Radiol ; 104: 136-142, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29857859

RESUMO

OBJECTIVES: Image quality in head and neck imaging is often severely hampered by artifacts arising from dental implants. This study evaluates metal artifact (MA) reduction using virtual monoenergetic images (VMI) compared to conventional CT images (CI) from spectral-detector computed tomography (SDCT). METHODS: 38 consecutive patients with dental implants were included in this retrospective study. All examinations were performed using a SDCT (IQon, Philips, Best, The Netherlands). Images were reconstructed as conventional images (CI) and as VMI in a range of 40-200 keV (10 keV increment). Quantitative image analysis was performed ROI-based by measurement of attenuation (HU) and standard deviation in most pronounced hypo- and hyperdense artifact, fat and soft tissue with presence of artifacts. Qualitatively, extent of artifact reduction, assessment of soft palate and cheeks were rated on 5-point Likert-scales by two radiologists. Statistical data evaluation included ANOVA and Wilcoxon-test with correction for multiple comparisons; interrater-agreement was determined by intraclass-correlation coefficient (ICC). RESULTS: The hypo- and hyperattenuating artifacts showed an increase and decrease of HU-values in VMIhigh (CI/VMI200 keV: -218.7/-174.4 HU, p = 0.1; and 309.8/119.2, p ≤ 0.05, respectively). Artifacts in the fat, as depicted by image noise did also decrease in VMIhigh (CI/VMI200 keV: 23.9/16.4, p ≤ 0.05). Qualitatively, hyperdense artifacts were decreased significantly in VMI ≥100 keV (e.g. CI/VMI200 keV: 2(1-3)/3(1-5), p ≤ 0.05). Artifact reduction resulted in improved assessment of the soft palate and cheeks (e.g. CI/VMI200 keV: 2(1-4)/3(1-5) and 2(1-5)/3(1-5), p ≤ 0.05). Overall interrater agreement was good (ICC = 0.77). CONCLUSIONS: Virtual monoenergetic images from SDCT reduce metal artifacts from dental implants and improve diagnostic assessment of surrounding soft tissue.


Assuntos
Artefatos , Implantes Dentários , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Imagens de Fantasmas , Intensificação de Imagem Radiográfica , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
11.
Skeletal Radiol ; 47(2): 195-201, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28932962

RESUMO

OBJECTIVE: Aim of this study was to assess the artifact reduction in patients with orthopedic hardware in the spine as provided by (1) metal-artifact-reduction algorithms (O-MAR) and (2) virtual monoenergetic images (MonoE) as provided by spectral detector CT (SDCT) compared to conventional iterative reconstruction (CI). METHODS: In all, 28 consecutive patients with orthopedic hardware in the spine who underwent SDCT-examinations were included. CI, O-MAR and MonoE (40-200 keV) images were reconstructed. Attenuation (HU) and noise (SD) were measured in order to calculate signal-to-noise ratio (SNR) of paravertebral muscle and spinal canal. Subjective image quality was assessed by two radiologists in terms of image quality and extent of artifact reduction. RESULTS: O-MAR and high-keV MonoE showed significant decrease of hypodense artifacts in terms of higher attenuation as compared to CI (CI vs O-MAR, 200 keV MonoE: -396.5HU vs. -115.2HU, -48.1HU; both p ≤ 0.001). Further, artifacts as depicted by noise were reduced in O-MAR and high-keV MonoE as compared to CI in (1) paravertebral muscle and (2) spinal canal-CI vs. O-MAR/200 keV: (1) 34.7 ± 19.0 HU vs. 26.4 ± 14.4 HU, p ≤ 0.05/27.4 ± 16.1, n.s.; (2) 103.4 ± 61.3 HU vs. 72.6 ± 62.6 HU/60.9 ± 40.1 HU, both p ≤ 0.001. Subjectively both O-MAR and high-keV images yielded an artifact reduction in up to 24/28 patients. CONCLUSION: Both, O-MAR and high-keV MonoE reconstructions as provided by SDCT lead to objective and subjective artifact reduction, thus the combination of O-MAR and MonoE seems promising for further reduction.


Assuntos
Algoritmos , Artefatos , Fixadores Internos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Razão Sinal-Ruído
13.
Eur J Clin Nutr ; 71(8): 995-1001, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28378853

RESUMO

BACKGROUND/OBJECTIVES: Fatty liver disease (FLD) is an important intermediate trait along the cardiometabolic disease spectrum and strongly associates with type 2 diabetes. Knowledge of biological pathways implicated in FLD is limited. An untargeted metabolomic approach might unravel novel pathways related to FLD. SUBJECTS/METHODS: In a population-based sample (n=555) from Northern Germany, liver fat content was quantified as liver signal intensity using magnetic resonance imaging. Serum metabolites were determined using a non-targeted approach. Partial least squares regression was applied to derive a metabolomic score, explaining variation in serum metabolites and liver signal intensity. Associations of the metabolomic score with liver signal intensity and FLD were investigated in multivariable-adjusted robust linear and logistic regression models, respectively. Metabolites with a variable importance in the projection >1 were entered in in silico overrepresentation and pathway analyses. RESULTS: In univariate analysis, the metabolomics score explained 23.9% variation in liver signal intensity. A 1-unit increment in the metabolomic score was positively associated with FLD (n=219; odds ratio: 1.36; 95% confidence interval: 1.27-1.45) adjusting for age, sex, education, smoking and physical activity. A simplified score based on the 15 metabolites with highest variable importance in the projection statistic showed similar associations. Overrepresentation and pathway analyses highlighted branched-chain amino acids and derived gamma-glutamyl dipeptides as significant correlates of FLD. CONCLUSIONS: A serum metabolomic profile was associated with FLD and liver fat content. We identified a simplified metabolomics score, which should be evaluated in prospective studies.


Assuntos
Fígado Gorduroso Alcoólico/sangue , Metabolismo dos Lipídeos , Fígado/metabolismo , Hepatopatia Gordurosa não Alcoólica/sangue , Idoso , Consumo de Bebidas Alcoólicas/efeitos adversos , Bancos de Espécimes Biológicos , Biomarcadores/sangue , Estudos de Coortes , Biologia Computacional , Estudos Transversais , Dipeptídeos/sangue , Sistemas Inteligentes , Fígado Gorduroso Alcoólico/diagnóstico por imagem , Fígado Gorduroso Alcoólico/metabolismo , Fígado Gorduroso Alcoólico/fisiopatologia , Feminino , Ácido Glutâmico/análogos & derivados , Ácido Glutâmico/sangue , Humanos , Fígado/diagnóstico por imagem , Fígado/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Metabolômica/métodos , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/metabolismo , Autorrelato , Índice de Gravidade de Doença
14.
J Hand Surg Eur Vol ; 42(4): 370-376, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27573130

RESUMO

Surgical reconstruction of the interosseous membrane may restore longitudinal forearm stability in Essex-Lopresti lesions. This study aimed to compare the longitudinal stability of the intact forearm with a single-bundle and a double-bundle reconstruction of the central band of the interosseous membrane using digital image correlation with a three-dimensional camera system. Single and cyclic axial loading of eight fresh-frozen forearm specimens was carried out in the intact state, after creation of an Essex-Lopresti lesion, after a single-bundle and after a double-bundle reconstruction of the central band using a TightRope® (Arthrex GmbH, Munich, Germany) construct. Instability significantly increased after creation of an Essex-Lopresti lesion. The stability of intact specimens was similar to both reconstruction techniques. The results of this study suggest that TightRope® reconstruction of the central band restores longitudinal forearm stability. However, the single-bundle technique may be less reliable than double-bundle reconstruction. LEVEL OF EVIDENCE: Basic Science Study.


Assuntos
Fixadores Internos , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Suturas , Idoso de 80 Anos ou mais , Cadáver , Feminino , Antebraço , Humanos , Luxações Articulares/complicações , Instabilidade Articular/etiologia , Masculino , Fraturas do Rádio/complicações , Amplitude de Movimento Articular/fisiologia , Suporte de Carga/fisiologia , Traumatismos do Punho/complicações
15.
Orthop Traumatol Surg Res ; 101(8): 913-7, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26522382

RESUMO

OBJECTIVES: To investigate if intraoperative 3D flat panel imaging improves the detection of radiocarpal intraarticular screw misplacement (RCSM) in comparison to standard postoperative x-ray. METHODS: In a study on cadaver specimens, we evaluated the sensitivity and specificity to detect RCSM using X-ray, intraoperative 3D-fluoroscopy as well as the digital volume tomography. The gold standard reference was computed tomography. RESULTS: Sensitivity for the detection of RCSM for X-ray was 58% and specificity 88%. For DVT, the sensitivity to detect RCSM was 88% and the specificity 53%. For 3D-fluoroscopy, the sensitivity for RCSM was 68% and specificity 95%. When combining the methods, the best performance was found, when combining the two intraoperative imaging methods, with a resulting sensitivity of 88% and a specificity of 73%. CONCLUSIONS: Intraoperative 3D fluoroscopy and digital volume tomography appear to be at least as sensitive and specific to detect RCSM than the regular postoperative radiography in two planes. However, especially discrete screw misplacements can be missed with either method. LEVEL OF EVIDENCE: Level IV. Diagnostic device study.


Assuntos
Parafusos Ósseos/efeitos adversos , Tomografia Computadorizada de Feixe Cônico , Fluoroscopia/métodos , Imageamento Tridimensional , Articulação do Punho/diagnóstico por imagem , Placas Ósseas , Cadáver , Fixação Interna de Fraturas/métodos , Humanos , Cuidados Intraoperatórios , Período Pós-Operatório , Rádio (Anatomia)/cirurgia , Fraturas do Rádio/cirurgia , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Articulação do Punho/cirurgia
16.
Eur J Radiol ; 84(11): 2269-74, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26283192

RESUMO

PURPOSE: In patients with multiple myeloma (MM), computed tomography is widely used for staging and to detect fractures. Detecting patients at severe fracture risk is of utmost importance. However the criteria for impaired stability of vertebral bodies are not yet clearly defined. We investigated the performance of parameters that can be detected by the radiologist for discrimination of patients with and without fractures. METHODS AND MATERIALS: We analyzed 128 whole body low-dose CT of MM patients. In all scans a QCT calibration phantom was integrated into the positioning mat (Image Analysis Phantom(®)). A QCT-software (Structural Insight) performed the volumetric bone mineral density (vBMD) measurements. Description of fracture risk was provided from the clinical radiological report. Suspected progressive disease (PD) was reported by the referring clinicians. Two radiologists that were blinded to study outcome reported on the following parameters based on predefined criteria: reduced radiodensity in the massa lateralis of the os sacrum (RDS), trabecular thickening and sclerosis of three or more vertebrae (TTS), extraosseous MM manifestations (EOM), visible small osteolytic lesions up to a length of 8mm (SO) and osteolytic lesions larger than 8mm (LO). Prevalent vertebral fractures (PVF) were defined by Genant criteria. Age-adjusted standardized odds ratios (sOR) per standard deviation change were derived from logistic regression analysis and area under the curve (AUC) from receiver operating characteristics (ROC) analyses were calculated. ROC curves were compared using the DeLong method. RESULTS: 45% of the 128 patients showed PVF (29 of 75 men, 24 of 53 women). Patients with PVF were not significantly older than patients without fractures (64.6 ± 9.2 vs. 63.3 ± 12.3 years: mean ± SD, p=0.5). The prevalence of each parameter did not differ significantly by sex. Significant fracture discrimination for age adjusted single models was provided by the parameters vBMD (OR 3.5 [1.4-8.8], AUC=0.64 ± 0.14), SO (sOR 1.6[1.1-2.2], AUC=0.63 ± 0.05), LO (sOR 2.1[1.1-4.2] AUC=0.69 ± 0.05) and RDS (sOR 2.6[1.6-4.7], AUC=0.69 ± 0.05). Multivariate models of these four parameters showed a significantly stronger association with the development of PVF (AUC=0.80 ± 0.04) than single variables. TTS showed a significant association with PVF in men(sOR 1.5 [0.8-3.0], AUC=0.63 ± 0.08), but not in women (sOR 2.3[1.4-3.7], AUC=0.70 ± 0.07). PD was significantly associated with PVF in women (sOR 1.9[1.1-3.6], AUC=0.67 ± 0.08) but not in men (sOR 1.4[0.9-2.3], AUC=0.57 ± .07). EOM were not associated with PVF (sOR 1.0[0.4-2.6], AUC=0.51 ± .05). CONCLUSION: In multiple myeloma, focal skeletal changes in low dose CT scans show a significant association with prevalent vertebral fractures. The combination of large osteolytic lesions and loss in radiodensity as can be detected with simple CT Hounsfield measurements of the os sacrum or BMD measurements showed the strongest association to fractures and may be of value for prospective studies.


Assuntos
Densidade Óssea , Mieloma Múltiplo/complicações , Osteólise/complicações , Osteólise/diagnóstico por imagem , Fraturas da Coluna Vertebral/complicações , Fraturas da Coluna Vertebral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Estudos Transversais , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/patologia , Fraturas por Osteoporose , Prevalência , Curva ROC , Esclerose , Fraturas da Coluna Vertebral/patologia , Tomografia Computadorizada por Raios X/métodos
17.
Rofo ; 187(10): 906-14, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26085175

RESUMO

PURPOSE: To compare the radiation doses and image qualities of computed tomography (CT)-guided interventions using a standard-dose CT (SDCT) protocol with filtered back projection and a low-dose CT (LDCT) protocol with both filtered back projection and iterative reconstruction. MATERIALS AND METHODS: Image quality and radiation doses (dose-length product and CT dose index) were retrospectively reviewed for 130 patients who underwent CT-guided lung interventions. SDCT at 120 kVp and automatic mA modulation and LDCT at 100 kVp and a fixed exposure were each performed for 65 patients. Image quality was objectively evaluated as the contrast-to-noise ratio and subjectively by two radiologists for noise impression, sharpness, artifacts and diagnostic acceptability on a four-point scale. RESULTS: The groups did not significantly differ in terms of diagnostic acceptability and complication rate. LDCT yielded a median 68.6% reduction in the radiation dose relative to SDCT. In the LDCT group, iterative reconstruction was superior to filtered back projection in terms of noise reduction and subjective image quality. The groups did not differ in terms of beam hardening artifacts. CONCLUSION: LDCT was feasible for all procedures and yielded a more than two-thirds reduction in radiation exposure while maintaining overall diagnostic acceptability, safety and precision. The iterative reconstruction algorithm is preferable according to the objective and subjective image quality analyses. KEY POINTS: Implementation of a low-dose computed tomography (LDCT) protocol for lung interventions is feasible and safe. LDCT protocols yield a significant reduction (more than 2/3) in radiation exposure. Iterative reconstruction algorithms considerably improve the image quality in LDCT protocols.


Assuntos
Biópsia Guiada por Imagem/métodos , Pneumopatias/diagnóstico por imagem , Pneumopatias/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Doses de Radiação , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Estudos de Viabilidade , Feminino , Marcadores Fiduciais , Humanos , Processamento de Imagem Assistida por Computador , Pneumopatias/patologia , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Radiologia Intervencionista
18.
Graefes Arch Clin Exp Ophthalmol ; 237(11): 887-92, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10541897

RESUMO

BACKGROUND: Small-incision cataract surgery combined with trabeculectomy offers new options for surgical treatment of patients with glaucoma and cataract. The purpose of this prospective randomized study was to compare the efficacy and safety of two different techniques of combined surgery: a one-site and a two-site approach. METHODS: Fifty eyes of 50 patients were included in this study. Twenty-five patients were randomly assigned to the one-site procedure and 25 patients to the two-site procedure. The one-site approach consisted of a superior tunnel phacoemulsification under a scleral flap with subsequent trabeculectomy. The two-site approach included a temporal corneal phacoemulsification combined with a separate-incision superior trabeculectomy. RESULTS: The preoperative mean intraocular pressure (IOP) of 29.8+/-4.9 mmHg dropped significantly to 15.9+/-3.2 mmHg. The mean follow-up time was 19+/-4. 3 months (range 4-25 months). The reduction of IOP was more pronounced in the two-site group (50.1%) than in the one-site group (43%), but the difference was not statistically significant. Patients needed 2.2+/-1.7 antiglaucomatous medications preoperatively vs 0.52+/-1.39 postoperatively. Three patients (6%) required needling of encapsulated bleb, and two patients underwent a reoperation to control IOP. Mean visual acuity improved from 0. 14+/-0.36 to 0.38+/-0.30 postoperatively. The most common complications after combined surgery were fibrinous exudation (24%) and hyphema (12%). CONCLUSION: Both techniques of combined cataract and glaucoma surgery proved to be efficient and safe procedures to control IOP and to improve visual acuity. The reduction of IOP did not differ between the one-site approach and the two-site approach.


Assuntos
Glaucoma de Ângulo Fechado/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Facoemulsificação/métodos , Trabeculectomia/métodos , Idoso , Idoso de 80 Anos ou mais , Catarata/complicações , Síndrome de Exfoliação/complicações , Feminino , Glaucoma de Ângulo Fechado/complicações , Glaucoma de Ângulo Aberto/complicações , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Segurança , Retalhos Cirúrgicos , Resultado do Tratamento , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...